Page 70 - Kingbright 2022-2023 catalog
P. 70

TECHNICAL NOTES


       TECHNICAL DATA

        Super Bright Yellow                                   SY : AlGaInP

              Forward Current vs.        Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
              Forward Voltage            Forward Current                                       Ambient Temperature
           50                         2.5                        50                         2.5
              T a  = 25 °C            2.0  T a  = 25 °C          40                         2.0
           40
          Forward current (mA)  30  Luminous intensity normalised at  20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised at  T a = 25 °C  1.5

                                                                                            1.0
           20
                                                                 20
                                      1.0
           10
                                                                                            0.0
            0                         0.5                        10 0                       0.5
                                      0.0
             1.5  1.7  1.9  2.1  2.3  2.5  0  10  20  30  40  50  -40 -20  0  20  40  60  80 100  -40 -20  0  20  40  60 80 100
                 Forward voltage (V)        Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
        Super Bright Yellow                                    SYK/J3 : AlGaInP

              Forward Current vs.        Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
              Forward Voltage            Forward Current                                       Ambient Temperature
           50                         2.5                        50                         2.5
              T a  = 25 °C            2.0  T a  = 25 °C          40                         2.0
          Forward current (mA)  30  Luminous intensity normalised at  20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised at  T a = 25 °C  1.5
           40

           20
                                      1.0
                                                                 20
                                                                                            1.0
           10
                                      0.0
            0                         0.5                        10 0                       0.5
                                                                                            0.0
             1.5  1.7  1.9  2.1  2.3  2.5  0  10  20  30  40  50  -40 -20  0  20  40  60  80 100  -40 -20  0  20  40  60 80 100
                 Forward voltage (V)        Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
        Blue                                                  QB/D : InGaN

              Forward Current vs.        Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
              Forward Voltage            Forward Current                                       Ambient Temperature
            50                        2.5                        50                         2.5
               T a  = 25 °C               T a  = 25 °C
            40                        2.0                        40                         2.0
          Forward current (mA)  30  Luminous intensity normalised  at 20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised  at T a = 25 °C  1.5

                                      1.0
            20
                                                                                            1.0
                                                                 20
            10
            0                         0.5                        10 0                       0.5
                                      0.0
                                                                                            0.0
             2.0  2.4  2.8  3.2  3.6  4.0  0  10  20  30  40  50  -40 -20  0  20  40  60  80 100  -40 -20  0  20 40  60  80 100
                  Forward voltage (V)       Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
        Blue                                                  VB/D : InGaN

              Forward Current vs.        Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
              Forward Voltage            Forward Current                                       Ambient Temperature
           50                         2.5                        50                         2.5
               T a  = 25 °C               T a  = 25 °C
           40                         2.0                        40                         2.0
          Forward current (mA)  30  Luminous intensity normalised  at 20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised  at T a = 25 °C  1.5


           20
                                                                                            1.0
                                      1.0
                                                                 20
           10
            0                         0.5                        10 0                       0.5
                                                                                            0.0
                                      0.0
             2.0  2.4  2.8  3.2  3.6  4.0  0  10  20  30  40  50  -40 -20  0  20  40  60  80 100  -40 -20  0  20 40  60  80 100
                  Forward voltage (V)       Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
       68    www.KingbrightUSA.com
   65   66   67   68   69   70   71   72   73   74   75