Page 64 - Kingbright 2022-2023 catalog
P. 64

TECHNICAL NOTES


       TECHNICAL DATA

        High Efficiency Red,Orange                            E,I : GaAsP/GaP

             Forward Current vs.         Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
             Forward Voltage             Forward Current                                      Ambient Temperature
           50                         2.5                        50                         2.5
              T a  = 25 °C            2.0  T a  = 25 °C          40                         2.0
           40
          Forward current (mA)  30  Luminous intensity normalised at  20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised at  T a = 25 °C  1.5


           20
                                                                                            1.0
                                                                 20
                                      1.0
           10
                                                                                            0.0
                                      0.0
            0                         0.5                        10 0                       0.5
            1.5  1.7  1.9  2.1  2.3  2.5  0  10  20  30  40  50   -40 -20  0  20  40  60  80 100  -40 -20  0  20  40  60 80 100
                 Forward voltage (V)        Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
        Bright Red                                            H : GaP
             Forward Current vs.         Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
             Forward Voltage             Forward Current                                      Ambient Temperature
           50                         2.5                        50                         2.5
              T a  = 25 °C            2.0  T a  = 25 °C          40                         2.0
           40
          Forward current (mA)  30     Luminous intensity normalised at  20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised  at T a = 25 °C  1.5

                                      1.0
                                                                 20
           20
                                                                                            1.0
           10
                                      0.0
                                                                                            0.0
            0                         0.5                        10 0                       0.5
            1.7  1.9  2.1  2.3  2.5  2.7  0  10  20  30  40  50   -40 -20  0  20  40  60  80 100  -40 -20  0  20  40  60 80 100
                 Forward voltage (V)        Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
        Super Bright Red                                      SR : GaAlAs

             Forward Current vs.         Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
             Forward Voltage             Forward Current                                      Ambient Temperature
           50                         2.5                        50                         2.5
              T a  = 25 °C            2.0  T a  = 25 °C          40                         2.0
           40
          Forward current (mA)  30  Luminous intensity normalised at  20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised  at T a = 25 °C  1.5

                                      1.0
                                                                 20
                                                                                            1.0
           20
           10
                                                                                            0.0
                                      0.0
            0                         0.5                        10 0                       0.5
            1.5  1.7  1.9  2.1  2.3  2.5  0  10  20  30  40  50   -40 -20  0  20  40  60  80 100  -40 -20  0  20  40  60 80 100
                 Forward voltage (V)        Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
        Super Bright Red                                      SR/J4 : AlGaInP

             Forward Current vs.         Luminous Intensity vs.    Forward Current Derating  Curve  Luminous Intensity vs.
             Forward Voltage             Forward Current                                      Ambient Temperature
           50                         2.5                        50                         2.5
              T a  = 25 °C            2.0  T a  = 25 °C          40                         2.0
           40
          Forward current (mA)  30     Luminous intensity normalised at  20 mA  1.5  Permissible forward current (mA)  30  Luminous intensity normalised  at T a = 25 °C  1.5


                                                                 20
                                                                                            1.0
                                      1.0
           20
           10
                                                                                            0.0
                                      0.0
            0                         0.5                        10 0                       0.5
            1.5  1.7  1.9  2.1  2.3  2.5  0  10  20  30  40  50   -40 -20  0  20  40  60  80 100  -40 -20  0  20  40  60 80 100
                 Forward voltage (V)        Forward current (mA)     Ambient temperature (°C)   Ambient temperature (°C)
       62    www.KingbrightUSA.com